SRT5KXLT

SPD_JPRO-9WRL2Q_FL_V

APC Smart-UPS On-Line, 5.4kVA, Tower, 208V, 2x L6-20R+2x L6-30R NEMA outlets, Network Card+SmartSlot, Extended runtime, W/O rail kit

Main
Main Input Voltage
208 V AC 1 phase
Input voltage
240 V
Input Connection Type
NEMA L6-30P
Input voltage limits
100...275 V adjustable (half load)
Network frequency
40...70 Hz auto-sensing
Output voltage
208 V 1 phase
Output voltage
240 V
Rated power in W
4800 W
Rated power in VA
5400 VA
Output connection type
2 NEMA
Bypass type
Internal bypass (automatic and manual)
Crest factor
3 : 1
Harmonic distortion
Less than 2 %
Maximum configurable power in VA
5400 VA
Maximum configurable power in W
4800 W
UPS type
On-Line
Wave type
Sine wave
Output frequency
50/60 Hz +/- 3 Hz sync to mains
Complementary
Battery type
Lead-acid internal included
Emergency power off
Yes
Free slots
1
Preinstalled device
Network management card 3 with environmental monitoring
Alarm
Audible and visible alarms : prioritized by severity
UPS connectivity
Serial port
USB port
Pre-installed network management card 3
Surge energy rate
480 J
Cable length
3.05 m
Number of cables
1
Colour
Black
Width
130 mm
Height
432 mm
Depth
719 mm
Net weight
55.79 kg
Mounting location
Front
Mounting preference
No preference
Mounting mode
Rack-mounted with kit
USB compatible
Yes
Mounting mode
Rack-mounted with included kit
Provided equipment
CD with software
Documentation CD
Installation guide
Removable support feet
Temperature probe
USB cable
Warranty card
Web/SNMP management card
Additional specification
High density
Redundant
No
Product or component type
Uninterruptible power supply (UPS)
Range of product
Smart-UPS On-Line
Curve equation
Efficiency
Curve fixed loss
0.0136
Curve load maximum
100 %
Curve load minimum
2 %
Curve proportional loss
0.0223
Curve square loss
0.0244
Curve test cond ID
Curve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 240V/60Hz electrical input and balanced resistive load (PF = 1.0) output.
Curve X-axis maximum
100 %
Curve X-axis minimum
0 %
Curve X-axis title
Load
Curve X-axis units
Percentage
Curve Y-axis maximum
100 %
Curve Y-axis minimum
50 %
Curve Y-axis title
Efficiency
Curve Y-axis units
Percentage
Graph display
1
Show note OP temperature
No
UPS size
S
Environment
Product certifications
ENERGY STAR V2.0 (USA)
NOM
Ambient air temperature for operation
0…40 °C
Ambient air temperature for storage
-15…45 °C
Storage altitude
0…15240 m
IP degree of protection
IP20
Relative humidity
0…95 % non-condensing
Storage Relative Humidity
0…95 % non-condensing
Acoustic level
55 dBA
Heat dissipation
1047 Btu/h
Operating altitude
0...10000 ft
Batteries & Runtime
Battery type
Lead-acid battery
Battery voltage
192 V
Extended runtime
1
Battery recharge time
1.5 h
Number of battery replacement quantity
1
Battery life
3…5 year(s)
Battery charger power
556 W rated
Battery curve
D
Battery design life
2 year(s)
UPS design life
7 year(s)
Battery power in VAH
840 VAh runtime
Battery option
SRT192BP 1 2520 VAh
SRT192BP 2 4200 VAh
SRT192BP 3 5880 VAh
SRT192BP 4 7560 VAh
SRT192BP 5 9240 VAh
SRT192BP 6 10920 VAh
SRT192BP 7 12600 VAh
SRT192BP 8 14600 VAh
SRT192BP 9 16280 VAh
SRT192BP 10 17640 VAh
General
Number of tare power
77 W
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
33 cm
Package 1 Width
96 cm
Package 1 Length
61 cm
Package 1 Weight
64.41 kg
Contractual warranty
Warranty (in months)
24 Battery|36 UPS

Offer SustainabilityOffer Sustainability

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data Explained
Recyclability potential, in %
65
Total lifecycle Carbon footprint
11 486 kg CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3]
814 kg CO2 eq.
Carbon footprint of the distribution phase [A4]
9 kg CO2 eq.
Carbon footprint of the installation phase [A5]
0 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6]
10655.6550216223
Carbon footprint of the use phase [B2, B3, B4, B6]
10 656 kg CO2 eq.
Sustainable packaging
No
Carbon footprint of the end-of-life phase [C1 to C4]
7.9354190769
Carbon footprint of the end-of-life phase [C1 to C4]
8 kg CO2 eq.
Environmental Disclosure
Total lifecycle Carbon footprint
11486
Average percentage of recycled plastic content
15 %
Packaging made with recycled cardboard
Yes
Packaging without single use plastic
No
California proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
ENERGY STAR®
ENERGY STAR UPS V2.0 (USA)
Removable battery
User replaceable
Take-back
No
WEEE Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
ページトップに戻るページトップに戻る