SRT3000RMXLA

SPD_JPRO-AC2JSB_FL_H

APC Smart-UPS On-Line, 3kVA, Rackmount 2U, 120V, 8x 5-20R+1x L5-30R NEMA outlets, SmartSlot, Extended runtime, W/ rail kit

Overview
Presentation
High density, double-conversion on-line power protection with scalable runtime.
Main
Main Input Voltage
120 V AC 1 phase
Input Connection Type
NEMA L5-30P
Network frequency
40...70 Hz auto-sensing
Output voltage
120 V 1 phase
Rated power in W
2700 W
Rated power in VA
3000 VA
Output connection type
8 NEMA
1 NEMA
Bypass type
Internal bypass (automatic and manual)
Crest factor
3 : 1
Harmonic distortion
Less than 2 %
Maximum configurable power in VA
3000 VA
Maximum configurable power in W
2700 W
UPS type
On-Line
Wave type
Sine wave
Output frequency
50/60 Hz +/- 3 Hz sync to mains
Complementary
Battery type
Lead-acid internal included
Emergency power off
Yes
Free slots
1
Alarm
Audible and visible alarms : prioritized by severity
UPS connectivity
Serial port
USB port
Surge energy rate
340 J
Number of rack unit
2U
Cable length
2.4 m
Number of cables
1
Colour
Black
Width
432 mm
Height
85 mm
Depth
635 mm
Net weight
31.3 kg
Mounting location
Front
Mounting preference
Lower
Mounting mode
Rack-mounted
USB compatible
Yes
Mounting position
Horizontal
Mounting mode
Rack-mounted with kit sold separately
Provided equipment
CD with software
Documentation CD
Installation guide
Rack mounting brackets
Rack mounting support rails
USB cable
Warranty card
Additional specification
High density
Redundant
No
Product or component type
Uninterruptible power supply (UPS)
Range of product
Smart-UPS On-Line
Performance multiplier
1
Value multiplier
1
Size UPS version
Internetworking
Server
Telecom
Curve equation
Efficiency
Curve fixed loss
0.0174
Curve load maximum
100 %
Curve load minimum
2 %
Curve proportional loss
0.0134
Curve square loss
0.0509
Curve test cond ID
Curve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 120V/60Hz electrical input and balanced resistive load (PF =1.0) output.
Curve X-axis maximum
100 %
Curve X-axis minimum
0 %
Curve X-axis title
Load
Curve X-axis units
Percentage
Curve Y-axis maximum
100 %
Curve Y-axis minimum
50 %
Curve Y-axis title
Efficiency
Curve Y-axis units
Percentage
Graph display
1
Show note OP temperature
No
UPS size
S
Environment
Product certifications
ENERGY STAR V2.0 (USA)
Ambient air temperature for operation
0…40 °C
Ambient air temperature for storage
-15…45 °C
Storage altitude
0…15240 m
IP degree of protection
IP20
Relative humidity
0…95 % non-condensing
Storage Relative Humidity
0…95 % non-condensing
Acoustic level
55 dBA
Heat dissipation
805 Btu/h
Operating altitude
0...10000 ft
Batteries & Runtime
Battery type
Lead-acid battery
Battery voltage
96 V
Extended runtime
1
Number of battery filled slots
1
Battery recharge time
3 h
Number of battery replacement quantity
1
Battery life
3…5 year(s)
Battery charger power
151 W rated
Battery curve
D
Battery design life
2 year(s)
UPS design life
7 year(s)
Battery power in VAH
454 VAh runtime
Battery option
SRT96RMBP 1 1362 VAh
SRT96RMBP 2 2270 VAh
SRT96RMBP 3 3178 VAh
SRT96RMBP 4 4086 VAh
SRT96RMBP 5 4994 VAh
SRT96RMBP 6 5902 VAh
SRT96RMBP 7 6801 VAh
SRT96RMBP 8 7718 VAh
SRT96RMBP 9 8626 VAh
SRT96RMBP 10 9534 VAh
General
Number of tare power
25 W
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
23.6 cm
Package 1 Width
34.3 cm
Package 1 Length
9.7 cm
Package 1 Weight
39.92 kg
Contractual warranty
Warranty (in months)
24 Battery|36 UPS

Offer SustainabilityOffer Sustainability

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data Explained
Recyclability potential, in %
65
Total lifecycle Carbon footprint
8 007 kg CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3]
482 kg CO2 eq.
Carbon footprint of the distribution phase [A4]
5 kg CO2 eq.
Carbon footprint of the installation phase [A5]
0 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6]
7514.4891951675
Carbon footprint of the use phase [B2, B3, B4, B6]
7 514 kg CO2 eq.
Mercury free
Yes
Sustainable packaging
No
Carbon footprint of the end-of-life phase [C1 to C4]
4.7018348308
Carbon footprint of the end-of-life phase [C1 to C4]
5 kg CO2 eq.
Environmental Disclosure
Total lifecycle Carbon footprint
8007
Average percentage of recycled plastic content
15 %
Packaging made with recycled cardboard
Yes
Packaging without single use plastic
No
California proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
ENERGY STAR®
ENERGY STAR UPS V2.0 (USA)
End of life manual availability
Removable battery
User replaceable
Take-back
No
WEEE Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
ページトップに戻るページトップに戻る