GP-Pro EX Ver. 5.01.000 released

DownloadUpdates & DriversGP-Pro EX

What's New: GP-Pro EX Ver. 5.01.000

Support of New Feature

Updated features

  • Supported Models
    - GP6000 Series (Advanced) is now supported.
    - GPH6000 Series (Handheld) is now supported.
    - PSA6000 Series is now supported.
  • GP6000/GPH6000 Series
    - Blink display is now supported in color settings.
  • GP6000 Series
    - PDF Viewer is now supported.
    - Pro-face Remote HMI is now supported.
    - IPsec is now supported.
    - During project transfer, the LED now lights up in green and orange.
  • LT4000 Series
    - IPsec is now supported.
  • WinGP
    - Touch buzzer sound output is now supported on the PS6000 Series.
  • Project Size
    - The maximum project size for the following models is now 128 MB:
    • GP6000 Series (Advanced)
    • GP6000 Series (Standard)
    • GPH6000 Series (Handheld)
    • PC/AT
    • PS-5000,PS(A)-6000
  • Number of Parts to Place
    - On GP6000 Series and GPH6000 Series, the maximum number of parts per screen is now 2000.
  • Number of Addresses to Read (D-Script)
    - On GP6000 Series and GPH6000 Series, the maximum number of addresses per screen is now 3000.
  • System Variables
    - You can now display and change the IP address, subnet mask, and default gateway via system variables.
  • Security
    - Added support for [User ID – Enhanced] mode, allowing you to set user IDs and passwords that are more secure than in previous versions.
  • Image USB
    - For models that do not support SD cards, it is now possible to specify USB (Image USB) instead of SD cards (Image SD).
    • Picture Display
    • Call Screen
  • Editor
    - We have started providing a 64-bit version of GP-ProEX. This allows you to edit larger projects than the 32-bit version. However, project operations that include D-Script may be slower in comparison to the 32-bit version. If you do not need to edit large projects, we recommend using the 32-bit version.
  • Image Font
    - When [Anti-alias] is ON, you can specify a transparent background color.
  • Data Display
    - You can now open the extended calculation expression editor directly from the property window.
  • Changing the Display Unit
    - When changing between handheld models, the conversion now supports realigning the position of function keys.
  • Parts
    - Added part shapes.
  • Simulation
    - When using GP6000 Series (Standard) projects, the address tab now supports monitoring the status of time update settings.
  • Version Reverter
    - Reverting to versions down to V5.00.000 is now supported. Reverting to versions V4.09.600 or earlier is not supported.

 

Updated communication protocols

  • New communication driver is supported
    The following is now supported.
    - Schneider Electric XV USB Tower Light
    - Pro-face by Schneider Electric DM Link Communication
  • Upgrade to communication driver function
    • The following functions are now supported.
      • Digital Electronics CorporationGeneral Ethernet
      • Digital Electronics CorporationGeneral SIO
      • Digital Electronics CorporationMemory Link
      • Digital Electronics CorporationNo connection
        - Manufacturer name has changed.
        Digital Electronics Corporation -> Pro-face by Schneider Electric
      • Schneider Electric SAMODBUS SIO Master
      • Schneider Electric SAMODBUS Slave
      • Schneider Electric SAMODBUS TCP Master
      • Schneider Electric SAUni-Telway
        - Manufacturer name has changed.
        Schneider Electric SA -> Schneider Electric
      • Schneider Electric MODBUS Slave
        - The accessible address range for each device has been expanded.
      • Siemens AG TIA Portal Ethernet
        - Secure communication is now supported on GP6000 Series and WinGP. When using WinGP, please install W32 OpenSSL V3 or later.
      • KEYENCE Corporation KV-700 - 8000, X - ETH
        - The import processing time has been improved.
      • OPC Foundation OPC UA Server/Client
        - OPC UA client functionality is now supported.
        - For secure communication, the server certificate must be registered.
        Register the server certificate in OPC UA Server under [Security
        Configuration] → [Certificate Configuration].
        - For secure communication, the certificate generated in the HMI must be
        extracted using a tool and registered in the OPC UA Server (OPC UA client certificate).
        One way to do this is to enable the OPC UA Server function on the HMI, start the HMI, and then connect using Unified Automation’s UaExpert.
        After connection, the certificate is created in the following folder: C:\Users\[UserName]\AppData\Roaming\unifiedautomation\uaexpert\PKI\ trusted\certs