1.5.3.2 SP5000 Series

Box Module

SP-5B00 Series

SP-5B00

SP-5B10

SP-5B90

SP-5B40*13, SP-5B41, SP-5B411, SP-5B412

 

Display Unit

       

 

Screen Area (Unit: byte)

64M

64M

64M

64M

5.5 Font Settings Guide

Portrait Installation

3.8.1.1 New - Display Unit and Model Settings

Function Expansion Memory

-

-

-

-

4.4.7 System Settings [Display Unit] - [Extended] Settings Guide

Installing the USB/RS-422/485 Conversion Adapters

-

6.9.1 System Settings [Device/PLC] Settings Guide

MAC Address Display

M.17.2.7 Main Unit - Ethernet settings

External Storage

       

 

CF Card

-

-

-

-

 

SD Card

 

CFast Card

-

-

-

4.7 Usable External Storage

USB storage

 

FTP server

-

 

System Settings

       

 

Drawing in 256 colors

1.6 Supported Colors

Reverse Display

-

-

-

-

4.4.2 System Settings [Display Unit] - [Display] Settings Guide

Blink

-

4.4.2.2 Display Unit [Display] - Display Settings

Faded Color Blink

-

4.4.2 System Settings [Display Unit] - [Display] Settings Guide

Synchronize Text Display with Text Table

4.4.2 System Settings [Display Unit] - [Display] Settings Guide

Enhanced System Password

4.4.3 System Settings [Display Unit] - [Operation] Settings Guide

Time Zone Settings

*5

4.4.2 System Settings [Display Unit] - [Display] Settings Guide

Detect Backlight Burnout

-

-

-

-

4.4.3 System Settings [Display Unit] - [Operation] Settings Guide

Dimmer settings

*1

*1

*1

-

4.4.2.1 Display Unit [Display] - Screen Settings

2 point touch / Multitouch

2 points*4

2 points*4

-

2 points*4

4.4.3 System Settings [Display Unit] - [Operation] Settings Guide

Display the SD/USB Removal Icon

-

4.4.4.4 Display Unit [Mode] - Memory Card Settings

Screen Capture

42.7 Saving the Current Screen At Runtime (Screen Capture)

SRAM Auto Backup

4.4.4.4 Display Unit [Mode] - Memory Card Settings

Image Font

5.3 Image Font

Bitmap Font

5.4 Bitmap Font

Standard Font

4.4.7 System Settings [Display Unit] - [Extended] Settings Guide

Port Control

*11

4.4.10 System Settings [Display Unit] - [Port Control] Settings Guide

Device/PLC Communication*2

       

 

Number of Device/PLC drivers that can communicate simultaneously

4

4

4

4

6.2 Connecting to Multiple Devices/PLCs

Specify Indirect Device

6.9.1 System Settings [Device/PLC] Settings Guide

Import Device/PLC tags

6.8 Using Device/PLC Tags

Ethernet Multilink

6.6 Connecting Multiple Display Units to One Device/PLC (Ethernet Multilink)

Device Monitor

42.5 Monitoring the Value of Device Addresses (Device Monitor)

Ladder Monitor

-

-

-

-

"PLC Ladder Monitor Operation Manual"

Transfer

       

 

Network Transfer

*7

*7

*7

34.3 Transferring Project Files via Ethernet (LAN)

USB Transfer

34.2 Transferring Project Files via USB Transfer Cable

Modem Transfer

-

34.9 Updating Remote Screen Data via Modem

SIO Transfer (COM Connection)

-

34.12.1.1 Transfer Settings

Memory loader feature

34.8 Transferring Project Files Using a CF Card or USB Storage

CF/SD Card Connection

34.6 Transferring Just Data to a CF/SD Card

Connection Key

34.14.4 How the Connection Key Works

Common Settings

       

 

Change Backlight Color

-

-

-

-

4.5.3 Common - Backlight Color Settings

Clock Update Settings

-

4.5.2 Common - Clock Update Settings

Start Screen Settings

-

4.5.4 Common Settings - Start Screen Settings

Date format on CSV file output

19.12.1.1 Alarm Settings (Common Settings)

24.11.4 Display/Save in CSV

Divide destination folders by file numbers

4.7.1 Destination Folder and File Name

Increase Alarm Type [Extended] settings and Text Table index numbers

19.12.1 Common Settings (Alarm) Settings Guide

17.7.1.1 Text Table Settings

Alarm Message Multiple Line Display

19.12.1.1 Alarm Settings (Common Settings)

Attach Data Value to Operation Log

22.10.2 Operation Log Settings

Changing passwords at run time (CSV file)

22.8 Editing Passwords Online

Changing passwords at run time (password change screen)

 

User ID Mode-Enhanced

22.10.1.1 Password Settings

Append Date/Time to CSV File Name

19.12.1.1 Alarm Settings (Common Settings)

24.11.4 Display/Save in CSV

Transfer sampling CSV file to FTP

-

24.11.4 Display/Save in CSV

Transferring Sampled Data to the Cloud

24.11.2.3 Mixed Address Settings and Random Data Formats

Indirectly specify Sampling Frequency and Alarm Settings

24.11.3 Mode

24.11.4.3 Display/Save in CSV/Data Settings - Alarm

Sampling data/Enhanced recipe data format co-exist

24.6 Collecting, Searching, and Sorting Various Data

Create a recipe (CSV data) index file at runtime

A.2.2.2 Word Type - #H System Variables

Enhanced Recipes

25.18 Enhanced Recipe Data Flow

Extended Script copy file function

21.11.6 File Operation

Global Trigger

4.5.1 Common Settings - Global Trigger Settings

Movie record/play feature

-

-

-

-

27.3 Recording Video

Use image unit

-

-

-

-

27.6 Displaying Multiple Video Camera Outputs Simultaneously

Sound Output Feature

-

26.1 Settings Menu

AUX

-

26.4 Triggering a Buzzer Sound from the Display Unit

Retentive Variables Function

30.3.2.4 Retentive Variable Settings

PDF Settings

-

-

-

-

28.2 Displaying and Operating a PDF from the Display Unit

Parts

       

 

Selector List

9.16 Selector List Parts Settings Guide

XY Graph

18.9 Displaying Sampled Data in a Scatter Graph

18.11 Displaying Current Values of Multiple Addresses All at Once in a Scatter Graph

Indirectly specify a block of Alarm parts

19.12.2.1 Show History - Basic Settings/Basic

Special Data Display [File Manager] sort function and default path

25.9.3.2 File Manager - Extended

Special Data Display Part [File Manager] copy file to FTP

-

25.9.3.1 File Manager - Basic

Message Display's Bulletin Message

16.5 Displaying the Same Message on Multiple Display Units (Bulletin Messages)

Image Sensor Display

27.9 Displaying Video Images of Image Sensor

Animation

20.1 Animation - General

Alarm History Message Flow Display

19.12.2.6 Show History - Display

Alarm History/Sampling Data/Enhanced Recipe Data Refine Search/Sort Function

19.10 Searching / Sorting Alarm History

24.6 Collecting, Searching, and Sorting Various Data

25.23 Searching and Sorting Enhanced Recipe Data

Alarm Analysis Function

19.11 Alarm Analysis for Operation Log and Sampling

Logic

       

 

Logic Program Operation

-

30.2.1 Using Logic Function

I/O Driver

-

*10

*10

-

31.1 Controlling External I/O

Function Block

-

30.8 Function Block (FB)

Network

       

 

RPA feature

-

-

-

-

36.1.1 Remote PC Access (RPA)

GP-Viewer EX

37.1.1 GP-Viewer EX

FTP Function

*14

*14

*14

-

37.7.1.2 Remote Viewer - FTP

Web Server

-*12

-*12

-*12

-

 

Camera-Viewer EX

-

-

-

-

 

Pro-face Remote HMI

*6

37.7.1.4 Remote Viewer - Pro-face Remote HMI

E-mail

37.6 Check Display Unit's Information by E-mail

GP Remote Printer Server

-

35.3.4 Procedure - Printing to a Network Printer

Pro-face Connect (Models you can register as SiteManager)

*8

*8

*8

*9

42.10 Using Pro-face Connect's System

IPsec

42.11 Encrypting Communication Data Using IPsec

DHCP Function

-

M.17.2.7 Main Unit - Ethernet settings

Changing the IP address using system variables

-

42.12 Changing the Display Unit IP Address Using System Variables

Input Equipment/Peripheral Equipment (USB Device)

       

 

USB Keyboard

15.3 Display Inputs from USB Keyboard/EZ Numpad

EZ Illuminated Switch

15.4 Monitoring/Operating Alarm with EZ Illuminated Switch

EZ Tower Light

Cockpit parts are listed on our support site*3

EZ Numpad

15.3 Display Inputs from USB Keyboard/EZ Numpad

15.5 Setting Up Functions on the EZ Numpad

EZ Fingerprint Recognition Unit

22.9 Logging in with Fingerprint Recognition

EZ LAN Adapter

-

-

-

-

M.17.2.7 Main Unit - Ethernet settings

*1 While dimmed, brightness settings you can use are 0 to 100.

*2 Depends on the type of connected PLC/Device.

*3 http://www.pro-face.com/trans/en/manual/1001.html

*4 Available only when connected to the Premium Display.

*5 You cannot configure the Time Zone settings in offline mode.

*6 You can also use the "Pro-face Remote HMI Server".

*7 Run forced transfer on LAN1 (Ethernet1 port).

*8 Define SiteManager settings in offline mode.
M.17.2.9 Main Unit - Remote Viewer Settings

*9 Set up SiteManager in a browser. For more information, refer to the "Pro-face Connect GateManager User Manual".
http://www.pro-face.com/trans/en/manual/1001.html

*10 Available only when connected to the Fieldbus master unit. For details, see the Fieldbus Master Unit Hardware Manual.

*11 Port control for SiteManager Embedded (Pro-face Connect) is not supported.

*12 Supported in V4.09.450 or earlier.

*13 When you use SP-5B40, install the update module to ensure your operating system is up to date. If the operating system is not up to date, project files cannot be transferred to SP-5B40.
Download and install the SP-5B40 update module from our support site.
https://www.pro-face.com/trans/en/manual/1106.html

*14 Supports encryption of transmission data using FTPS.

Display Module

 

SP-5400WA,

SP-5500WA,

SP-5600WA, SP-5600TA

SP-5500TP,

SP-5600TP,

SP-5660TP,

SP-5700TP

SP-5700WC,

SP-5800WC

SP-5490WA, SP-5690WA, SP-5790W

 

2 point touch / Multitouch

-

2 points

2 points

-

4.4.3 System Settings [Display Unit] - [Operation] Settings Guide

Brightness sensor

-

-

M.2.3 Adjusting the Display Brightness Automatically Based on Ambient Brightness

Front USB

-

-

M.28.1.1 Peripheral Settings - Enable/Disable USB