GP4000M系列選購配件

序列線

產品名稱 型號 說明
RS-232C Cable (5m) CA3-CBL232/5M-01 Connects a host controller to the GP unit. (RS-232C)
RS-422 Cable (5m) CA3-CBL422/5M-01 Connects a host controller to the GP unit. (RS-422)
Mitsubishi PLC Q-Series Link Cable (5m) CA3-CBLLNKMQ-01 Connects Mitsubishi PLC Q-Series (or other host controller) to the GP unit. (RS-232C)
Omron PLC SYSMAC Link Cable (5m) CA3-CBLSYS-01 Connects Omron PLC SYSMAC Series unit (or other host controller) to the GP unit. (RS-232C)
Mitsubishi PLC A-Series Connection Cable (5m) CA3-CBLA-01 Connects Mitsubishi PLC A, QnA Series programming console I/F to GP unit. (Simultaneous use of programming console is not possible.)
Mitsubishi PLC Q-Series Connection Cable (5m) CA3-CBLQ-01 Connects Mitsubishi PLC Q-Series programming console I/F to GP unit. (Simultaneous use of programming console is not possible.)
Mitsubishi PLC FX-Series Connection Cable CA3-CBLFX/1M-01(1m) Connects Mitsubishi PLC FX-Series programming console I/F and GP unit. (Simultaneous use of programming console is not possible.)
CA3-CBLFX/5M-01(5m)
RS-422 Cable (5m) CA3-CBL422-01 Connects a host controller to the GP unit. (RS-422)
2 Port Adapter Cable (5m) CA3-MDCB11 Connects Mitsubishi PLC to the GP unit using 2 port adapter II (RS-422).
Mitsubishi PLC A, QnA, FX Series 2 Port Adapter II GP070-MD11 Allows simultaneous use of an GP unit Series unit and a Mitsubishi PLC A, QnA, FX Series peripheral device.
Terminal Block Conversion Adapter CA3-ADPTRM-01 Connects output from a serial interface with an RS-422 terminal block.
COM Port Conversion Adapter CA3-ADPCOM-01 Connects optional RS-422 communication items to GP unit's COM1 port.
Multi-Link Cable CA3-CBLMLT-01 (5m) Connects a host controller to the GP for multi-link (n:1) communication.
9-pin-to-25-pin RS-232C Conversion Cable CA3-CBLCBT232-01(0.2m) Connects a standard RS-232C cable (GP Connector, D-Sub 25-pin) to the GP.
9-pin-to-25-pin RS-422 Conversion Cable CA3-CBLCBT422-01(0.2m) Connects a standard RS-422 cable (GP Connector, D-Sub 25-pin) to the GP.
MPI Cable (3.5m) ST03-A2B-MPI21-PFE Connects a host controller to the GP unit for MPI communication.

USB線

產品名稱 型號 說明
EZ 三色漸層LED警示燈圓型底座管狀安裝款 PFXZCETWHA1 USB Connection Type Monolithic EZ Tower Light tube mounting with fixing plate.
EZ 三色漸層LED警示燈直接安裝款 PFXZCETWW1 USB Connection Type Monolithic EZ Tower with base mounting.
EZ 指示燈開關 PFXZCCEUSG1 A unit of 5 illuminated switches with multiple color LED easily connected with HMI via USB.
EZ 外接鍵盤 PFXZCCEUKB1 A unit of ten-key pad easily connected with HMI via USB.
EZ 指紋辨識模組 PFXZCCEUSS1 A unit of fingerprint identification easily connected with HMI via USB.
USB Front Cable (1m) CA5-USBEXT-01 Extension cable attaching USB interface to front panel.
USB-Serial (RS-232C) Conversion Cable (0.5m) CA6-USB232-01 Cable to convert the USB interface of a GP unit into a serial (RS-232C) interface.
USB Transfer Cable (USB Type A/mini B)(1.8 m) ZC9USCBMB1 Cable for transferring screen data from a PC (USB Type A) to the GP unit (USB mini B).
USB Panel-mount Extension Cable (USB mini B) (1 m) ZC9USEXMB1 Extension cable attaching to the USB (mini B) interface on the front side of the operation panel.

軟體

* " ** " is changed with the version of software.
產品名稱 型號 說明
GP-Pro EX PFXEXEDV** Screen editor software
(Ver. 2.71 or later required to use GP4000M Series)
GP-Pro EX Editor License *1 PFXEXEDLS** GP-Pro EX editor license
GP-Pro EX Editor Group License *2 10 licenses PFXEXGRPLS**10 GP-Pro EX editor group license
25 licenses PFXEXGRPLS**25
50 licenses PFXEXGRPLS**50
Pro-Server EX Ver.*.* PFXEXSDVV** Software that connects a PC to a GP via Ethernet and collects and transmits data 
Pro-Server EX Developer License *3*4 EX-SED-LICENSE Pro-Server EX developer license
Pro-Server EX Runtime License *5 EX-SRT-LICENSE Pro-Server EX Runtime license
GP-Viewer EX *6 1 licence EX-VIEWER-LICENSE License allowing a PC to access a GP4000 in remote mode.
10 licence EX-VIEWER-LICENSE-10
30 licence EX-VIEWER-LICENSE-30
Pro-face Remote HMI
(iPhone、iPad、iPod touch) V*.*
PFXEXRHIOSV** Software to operate Pro-face HMI screen on iPhone, iPad and iPod touch.
Pro-face Remote HMI
(Android) V*.*
PFXEXRHANDV** Software to operate Pro-face HMI screen on Android OS.
Pro-face Remote HMI Free
(Android) V*.*
PFXEXRHANDTRV** Free software to operate Pro-face HMI screen on tablets or smartphones with Android OS.

選購配件

產品名稱 型號 說明
Display module/Rear module separation cable (3m) *7 PFXZXMADSM3 Cable with hook to install a rear module on a DIN rail while connecting the rear module to a separated display module.
Display module/Rear module separation cable (5m) *7 PFXZXMADSM51
Panel Cutout Adapter *8 5.7-inch GP270-GP4000M-AT00 *9 Panel cutout adapter for mounting GP4000M Series in cutout of GP270, GP250, GP230
GP377-GP4000M-AT00 Panel cutout adapter for mounting GP4000M Series, LT4000M Series in cutout of GP-330*T/S/L, ST-330*T/S/B/W, GP-230*T/S/L, GP377, GP370
GP37W2-GP4000M-AT00 Panel cutout adapter for mounting GP4000M Series, LT4000M Series in cutout of GP37W2, LT (GLC150)
Screen Protection Sheet 3.5-inch CA6-DFS4-01
(GP-4201TM)
Disposable, dirt-resistant sheet for the GP unit's screen. (5 sheets/set)
5.7-inch PFXZCBDS61
(GP-4301TM)
UV Protection Sheet 3.5-inch PFXZCFUV41
(GP-4201TM)
Ultraviolet protection for the display (1 piece)
5.7-inch PFXZCFUV61
(GP-4301TM)

維修配件

* Please purchase when the product is damaged or lost.
產品名稱 型號 說明
Display Installation Nut PFXZGMNT1 Nut to install the display module (10 pcs/set)
Socket Wrench PFXZGMSW1 Socket wrench to tighten and loosen the display installation nut (1 pc/set)
DC Power Supply Connector PFXZGMCNDC1 Connector to connect DC power supply cables (5 pcs/set)
Accessories Kit PFXZGMAK1 Anti-rotation Tee, USB cable clamp to prevent disconnection (USB Type A, Mini B, for 1 port), 2mm-high spacer to adjust installation panel thickness (1pc/each)

*1Purchase this product when installing GP-Pro EX in a second or subsequent PC. One license is required for each PC.

*2 Group License consists of one set of Serial No./Key Code for installation on 10 PCs. (Should be used in the same office. Only supports GP-Pro EX Ver. 3.1.)

*3 This is available for the models with Ethernet port.

*4 Includes the settings editor and Runtime.

*5 Purchase this product when installing the settings editor and Run time in subsequent PCs.

*6 Purchase this license when installing only Run time in subsequent PCs. One license is required for each PC.

*7 GP-4201TM(PFXGM4201TAD) - the revisions, PV:03 RL:07 SV:4.0 or later are supported.
GP-4301TM(PFXGM4301TAD) - the revisions, PV:03 RL:08 SV:4.0 or later are supported.

*8 It is not guaranteed to use under the environment of IP65. Please confirm your usage environment before using this product in advance.

*9 LT4000M Series is not supported.