Serial Interface
| Product Name | Model No. | Description |
|---|---|---|
| RJ45 RS-232C Cable (5m) | PFXZLMCBRJR21 | Cable with loose wires at one end for RS-232C connection between various hosts and the LT. |
| RJ45 RS-485 Cable (5m) | PFXZLMCBRJR81 | Cable with loose wires at one end for RS-485 connection between various hosts and the LT. |
USB Interface
| Product Name | Model No. | Description |
|---|---|---|
| EZ Tower Light tube mounting with fixing plate | PFXZCETWHA1 | USB Connection Type Monolithic EZ Tower Light tube mounting with fixing plate EZ Tower Light Options |
| EZ Tower Light with base mounting | PFXZCETWW1 | USB Connection Type Monolithic EZ Tower with base mounting EZ Tower Light Options |
| EZ Illuminated Switch | PFXZCCEUSG1 | A unit of 5 illuminated switches with multiple color LED easily connected with LT via USB EZ Illuminated Switch Options |
| USB Transfer Cable (USB Type A/mini B) (1.8m) | ZC9USCBMB1 | Cable for transferring screen data from the PC (USB Type A) to LT (USB mini B) |
| USB Panelmount Extension Cable (USB Type A) (1m) | CA5-USBEXT-01 | Extension cable that attaches to USB (Type A) port of the LT |
| USB Panelmount Extension Cable (USB mini B) (1m) | ZC9USEXMB1 | Extension cable that attaches to USB (mini B) port of the LT |
| USB Cable (5m) | FP-US00 | Connects a USB printer (Type B) |
Software
* "* *" is changed with the version of software.
| Product Name | Model No. | Description | |
|---|---|---|---|
| GP-Pro EX | PFXEXEDV** | Screen-creation software | |
| GP-Pro EX Editor License*1*3 | PFXEXEDLS** | GP-Pro EX Editor License | |
| GP-Pro EX Editor Group License*1*2 | 10 licenses | PFXEXGRPLS**10 | GP-Pro EX editor group licenses |
| 25 licenses | PFXEXGRPLS**25 | ||
| 50 licenses | PFXEXGRPLS**50 | ||
| GP-Viewer EX | 1 licence | EX-VIEWER-LICENSE | License allowing a PC to access a LT in remote mode. |
| 10 licences | EX-VIEWER-LICENSE-10 | ||
| 30 licences | EX-VIEWER-LICENSE-30 | ||
| Pro-Server EX*4 | PFXEXSDVV** | Software that connects a PC to a LT via Ethernet and collects and transmits data | |
| Pro-Server EX Developer License*5 | EX-SED-LICENSE | Pro-Server EX developer license | |
| Pro-Server EX Runtime License*6 | EX-SRT-LICENSE | Pro-Server EX Runtime license | |
| Pro-face Remote HMI (iPhone, iPad, iPod touch) V*.* | PFXEXRHIOSV** | Software to operate Pro-face HMI screen on iPhone, iPad and iPod touch | |
| Pro-face Remote HMI (Android) V*.* | PFXEXRHANDV** | Software to operate Pro-face HMI screen on Android OS | |
| Pro-face Remote HMI Free (Android) V*.* | PFXEXRHANDTRV** | Free software to operate Pro-face HMI screen on tablets or smartphones with Android OS | |
| MES Action License | EX-MES-LICENSE-V** | License key permitting Pro-Server EX to access a database | |
Option Items
| Product Name | Model No. | Description | |
|---|---|---|---|
| Display module/Rear module separation cable (3m) | PFXZXMADSM31 | Cable with hook to install a rear module on a DIN rail while connecting the rear module to a separated display module | |
| Display module/Rear module separation cable (5m) | PFXZXMADSM51 | ||
| Screen Protection Sheet | 5-inch | PFXZCBDS61 (For LT-4301TM) | Disposable, dirt-resistant sheet for the unit's screen (5 sheet/set) (hard type) |
| UV Protection Sheet | 5-inch | PFXZCFUV61 (For LT-4301TM) | Ultraviolet protection for the display (1 piece) |
Maintenance Options
* Please purchase when the product is damage or lost.
| Product Name | Model No. | Description |
|---|---|---|
| LT4000M Analog model Rear Module | PFXLM4B01DAC | LT4000M Analog model Rear Module, Source Output, DC24V (Main Unit) |
| PFXLM4B01DAK | LT4000M Analog model Rear Module, Sink Output, DC24V (Main Unit) | |
| LT4000M DIO model Rear Module | PFXLM4B01DDC | LT4000M DIO model Rear Module, Source Output, DC24V (Main Unit) |
| PFXLM4B01DDK | LT4000M DIO model Rear Module, Sink Output, DC24V (Main Unit) | |
| Rear Module Installation Adapter | PFXZXMADSA1 | DIN rail installtion adapter for rear modules in non-display operation |
| 5.7 inch Display Module | PFXXM4300TP | For LT4000M/GP4000M Series Display Modular type, 5.7-inch |
| 3.5 inch Display Module | PFXXM4200TP | For LT4000M/GP4000M Series Display Modular type, 3.5-inch |
| DIO Connector for LT4000M | PFXZLMCNIO1 | I/O connector 15-pin (2 pcs/set) and I/O connector 6-pin (2 pcs/set) |
CANopen Slave Unit
TM3 CANopen Connection
CANopen unit
| Model No. | Description | Details | Guide Book | IO Configurator |
|---|---|---|---|---|
| TM3BCCO *8 | TM3 Bus Coupler CANopen | Product page | Modicon TM3 guidebook *Before using TM3, be sure to read this TM3 Guide book with recommended substitutes and precautions for replacing the EX module. | *TM3BC IO Configurator software is required to configure TM3BCCO and TM3. |
Modicon TM3 Module
| Model No. | Description | Details | Guide Book | IO Configurator |
|---|---|---|---|---|
| TM3DI8 | 8-ch Sink/Source Inputs (Screw) | Product page | Modicon TM3 guidebook *Before using TM3, be sure to read this TM3 Guide book with recommended substitutes and precautions for replacing the EX module. | *TM3BC IO Configurator software is required to configure TM3BCCO and TM3. |
| TM3DI8G | 8-ch Sink/Source Inputs (Spring) | Product page | ||
| TM3DI16 | 16-ch Sink/Source Inputs (Screw) | Product page | ||
| TM3DI16G | 16-ch Sink/Source Inputs (Spring) | Product page | ||
| TM3DQ8T | 8-ch Transistor Source Outputs (Screw) | Product page | ||
| TM3DQ8TG | 8-ch Transistor Source Outputs (Spring) | Product page | ||
| TM3DQ8U | 8-ch Transistor Sink Outputs (Screw) | Product page | ||
| TM3DQ8UG | 8-ch Transistor Sink Outputs (Spring) | Product page | ||
| TM3DQ8R | 8-ch Relay Outputs (Screw) | Product page | ||
| TM3DQ8RG | 8-ch Relay Outputs (Spring) | Product page | ||
| TM3DQ16TK | 16-ch Transistor Source Outputs (HE10) | Product page | ||
| TM3DQ16UK | 16-ch Transistor Sink Outputs (HE10) | Product page | ||
| TM3DQ16R | 16-ch Relay Outputs (Screw) | Product page | ||
| TM3DQ16RG | 16-ch Relay Outputs (Spring) | Product page | ||
| TM3DM8R | 4-ch Sink/Source Inputs, 4-ch Relay Outputs (Screw) | Product page | ||
| TM3DM8RG | 4-ch Sink/Source Inputs, 4-ch Relay Outputs (Spring) | Product page | ||
| TM3DM24R | 16-ch Sink/Source Inputs, 8-ch Relay Outputs (Screw) | Product page | ||
| TM3DM24RG | 16-ch Sink/Source Inputs, 8-ch Relay Outputs (Spring) | Product page | ||
| TM3AI2H | 2-ch Voltage/Current Inputs (Screw) | Product page | ||
| TM3AI2HG | 2-ch Voltage/Current Inputs (Spring) | Product page | ||
| TM3AQ2 | 2-ch Voltage/Current Outputs (Screw) | Product page | ||
| TM3AQ2G | 2-ch Voltage/Current Outputs (Spring) | Product page | ||
| TM3TI4 | 4-ch Voltage/Current or Temperature Inputs (Screw) | Product page | ||
| TM3TI4G | 4-ch Voltage/Current or Temperature Inputs (Spring) | Product page | ||
| TM3AM6 | 4-ch Voltage/Current Inputs, 2-ch Voltage/Current Outputs (Screw) | Product page | ||
| TM3AM6G | 4-ch Voltage/Current Inputs, 2-ch Voltage/Current Outputs (Spring) | Product page | ||
| TM3TM3 | 2-ch Temperature or Voltage/Current Inputs, 1-ch Voltage/Current Output (Screw) | Product page | ||
| TM3TM3G | 2-ch Temperature or Voltage/Current Inputs, 1-ch Voltage/Current Output (Spring) | Product page |
*1 LT4000M Series requires GP-Pro EX Ver. 3.12 or later.
*2 Group License consists of one set of Serial No./Key Code for installation on 10 PCs. (Should be used in the same office. Only supports GP-Pro EX Ver. 3.1.)
*3 Purchase this product when installing GP-Pro EX in a second or subsequent PC. One license is required for each PC.
*4 Includes the settings editor and Run time.
*5 Purchase this product when installing the settings editor and Run time in subsequent PCs.
*6 Purchase this license when installing only Run time in subsequent PCs. One license is required for each PC.
*7 It is not guaranteed to use under the environment of IP65. Please confirm your usage environment before using this product in advance.