Functional Comparison Table for Handy Type GP

GP4000H Series and GP3000H Series supported GP-Pro EX features are marked with "" (supported), or "-" (unsupported) in the following table.
 
 GP-3300HLGP-3300HSGP-3310HTGP-4311HTRefer to GP-Pro EX Reference Manual
Display UnitDisplay Unit6M6M8M32M6.5 Font Settings Guide
Portrait Installation----3.9.1.1 New - Display Unit and Model Settings
Function Expansion Memory----5.4.7 System Settings [Display Unit] - [Extended] Settings Guide
Installing the USB/RS-422/485 Conversion Adapters---7.9.1 System Settings [Device/PLC] Settings Guide
MAC Address DisplayM.17.2.7 Main Unit - Ethernet settings
External StorageCF Card-5.7 Usable External Storage
SD Card---
CFast Card----
USB storage
FTP server---
System SettingsDrawing in 256 colors-1.6 Supported Colors
Reverse Display--5.4.2 System Settings [Display Unit] - [Display] Settings Guide
Faded Color Blink5.4.2 System Settings [Display Unit] - [Display] Settings Guide
Synchronize Text Display with Text Table5.4.2 System Settings [Display Unit] - [Display] Settings Guide
Time Zone Settings----5.4.2 System Settings [Display Unit] - [Display] Settings Guide
Detect Backlight Burnout-5.4.3 System Settings [Display Unit] - [Operation] Settings Guide
Dimmer settings---5.4.2.1 Display Unit [Display] - Screen Settings
2 point touch / Multitouch----5.4.3 System Settings [Display Unit] - [Operation] Settings Guide
Display the SD/USB Removal Icon---5.4.4.4 Display Unit [Mode] - Memory Card Settings
Screen Capture---41.6 Saving the Current Screen At Runtime (Screen Capture)
SRAM Auto Backup5.4.4.4 Display Unit [Mode] - Memory Card Settings
Image Font6.3 Image Font
Bitmap Font6.4 Bitmap Font
Standard Font5.4.7 System Settings [Display Unit] - [Extended] Settings Guide
Device/PLC Communication *1Number of Devices/PLCs that can communicate simultaneously22247.2 Connecting to Multiple Devices/PLCs
Specify Indirect Device7.9.1 System Settings [Device/PLC] Settings Guide
Import Device/PLC tags---7.8 Using Device/PLC Tags
Ethernet Multilink *2 *2 *27.6 Connecting Multiple Display Units to One Device/PLC (Ethernet Multilink)
Device Monitor41.4 Monitoring the Value of Device Addresses (Device Monitor)
Ladder Monitor---"PLC Ladder Monitor Operation Manual"
TransferNetwork Transfer34.3 Transferring Project Files via Ethernet (LAN)
Modem Transfer34.9 Updating Remote Screen Data via Modem
SIO Transfer (COM Connection)34.12.1.1 Transfer Settings
Memory loader feature34.8 Transferring Project Files Using a CF Card or USB Storage
CF/SD Card Connection34.6 Transferring Just Data to a CF/SD Card
Common SettingsChange Backlight Color----5.5.2 Common - Backlight Color Settings
Clock Update Settings---5.5.1 Common - Clock Update Settings
Start Screen Settings---5.5.3 Common Settings - Start Screen Settings
Date format on CSV file output20.12.1.1 Alarm Guide
25.9.4 Display/Save in CSV
Divide destination folders by file numbers5.7.1 Destination Folder and File Name
Increase Alarm Type [Extended] settings and Text Table index numbers---20.12.1 Common Settings (Alarm) Settings Guide
18.7.1.1 Text Table Settings
Alarm Message Multiple Line Display20.12.1.1 Alarm Guide
Attach Data Value to Operation Log23.10.2 Operation Log Settings
Changing passwords at run time (CSV file)23.8 Editing Passwords Online
Changing passwords at run time (password change screen)---
Indirectly specify Sampling Frequency and Alarm Settings25.9.3 Mode
25.9.4.3 Display/Save in CSV/Data Settings - Alarm
Sampling data/Enhanced recipe data format co-exist---25.6 Collecting, Searching, and Sorting Various Data
Create a recipe (CSV data) index file at runtimeA.2.2.2 Word Type - #H System Variables
Enhanced Recipes---26.18 Enhanced Recipe Data Flow
Extended Script copy file function22.11.6 File Operation
Movie record/play feature----28.3 Recording Video
Use image unit----28.6 Displaying Multiple Video Camera Outputs Simultaneously
Sound Output Feature----27.1 Settings Menu
AUX----27.4 Triggering a Buzzer Sound from the Display Unit
Retentive Variables Function---8.14.5 Common Settings (Symbol Variables) Settings Guide
PartsSelector List10.16 Selector List Parts Settings Guide
XY Graph19.9 Displaying Sampled Data in a Scatter Graph
19.11 Displaying Current Values of Multiple Addresses All at Once in a Scatter Graph
Picture Display [CF Image Display]/[SD Image Display] for showing JPEG files---9.6.4 CF Image Display/SD Image Display
Indirectly specify a block of Alarm parts20.12.2.1 Show History - Basic Settings/Basic
Special Data Display [File Manager] sort function and default path26.9.3.2 File Manager - Extended
Special Data Display Part [File Manager] copy file to FTP26.9.3.1 File Manager - Basic
Message Display's Bulletin Message17.5 Displaying the Same Message on Multiple Display Units (Bulletin Messages)
Image Sensor Display28.9 Displaying Video Images of Image Sensor
Animation21.1 Animation - General
Alarm History Message Flow Display---20.12.2.6 Show History - Display
Alarm History/Sampling Data/Enhanced Recipe Data Refine Search/Sort Function---20.10 Searching / Sorting Alarm History
25.6 Collecting, Searching, and Sorting Various Data
26.23 Searching and Sorting Enhanced Recipe Data
Alarm Analysis Function---20.11 Alarm Analysis for Operation Log and Sampling
Logic *3Logic Program Operation---30.2.1 Using Logic Function
I/O Driver----31.1 Controlling External I/O
Function Block---30.8 Function Block (FB)
NetworkNetwork---36.1.1 Remote PC Access (RPA)
GP-Viewer EX37.1.1 GP-Viewer EX
Web Server37.6.1 Web Server
Camera-Viewer EX----37.14.1 Camera-Viewer EX
Pro-face Remote HMI---37.18.1.5 Remote Viewer - Pro-face Remote HMI
GP Remote Printer Server---35.3.4 Procedure - Printing to a Network Printer
Input EquipmentUSB Keyboard16.3 Display Inputs from USB Keyboard/EZ Numpad
EZ Illuminated Switch----16.4 Monitoring/Operating Alarm with EZ Illuminated Switch
EZ Tower Light----Cockpit parts are listed on the Pro-face support site *4
EZ Numpad----16.3 Display Inputs from USB Keyboard/EZ Numpad
16.5 Setting Up Functions on the EZ Numpad
EZ Fingerprint Recognition Unit----23.9 Logging in with Fingerprint Recognition

*1 Depends on the type of connected PLC/Device.

*2 If this model is used as a master station, performance may deteriorate.

*3 Unable to use with USB-Serial (RS-232C) adaptor cable or USB/RS-422/485 conversion adapter.

*4 Access to the download pages of Cockpit Parts.

GP-Pro EX Ver. 4.06 for GP4000H download page