The following are the features and precautions for the ST6000 2nd Gen Series.
1.1.3 For Those Using a Display Unit Supporting GP-Pro EX Ver.5.00 and Later
The display unit is equipped with System Settings separate from offline mode. For details about System Settings, refer to the manual for the display unit.
The [Timezone] in the [System Settings] - [Date and Time] is ignored.
The [DNS Settings] in the [System Settings] - [Ethernet] are ignored.
When the [System Settings] - [Ethernet] - [IP Mode] is set to [Auto], the display unit automatically obtains an IP address when connected to the network but cannot resolve names because the [DNS Settings] are ignored. When you specify the display unit from the Transfer Tool or other means, specify the IP address displayed in [System Settings] - [Information].
Pro-face Remote HMI clients cannot browse the display unit’s System Settings screen. When the display unit displays the System Settings screen, the client displays the screen previously shown before it changed to the System Settings screen. In addition, you cannot switch to the System Settings screen in the Remote HMI Client, even if you touch the [System Settings] button in offline mode.
The integer type logic system variable #L_Version is not supported.
A.2.1.2 Integer Type Logic System Variables - #L System Variables
Logic monitor functions (Logic Monitor and Address Monitor) are not available when using PFXST6200AWA* in a portrait orientation.
The serial port (COM) on the ST6000 2nd Gen Series supports RS (RTS)/CS (CTS) control signals only. In the Device/PLC Settings and peripheral device settings, [Flow Control] cannot be set to [ER(DTR/CTS)].
For details about the available and unavailable features for the ST6000 2nd Gen Series, refer to the following.
1.4.12.2 ST6000 2nd Gen Series