Target Settings

Target

Property Description Data Type Minimum Value Maximum Value Read Write

DateAndTime.Date

Stores the date on the target.*1 Date 01/01/1970 00:00:00 12/31/2037 15:00:00
DateAndTime.Time Stores the time on the target.*1 TimeOfDate 01/01/1970 00:00:00 12/31/2037 15:00:00
DateAndTime.DateTime Stores the date and time on the target.*1 DateAndTime 01/01/1970 00:00:00 12/31/2037 15:00:00
DateAndTime.Year Stores the year on the target.*1 Integer 1970 2037
DateAndTime.Month Stores the month on the target.*1 Integer 1 12
DateAndTime.Day Stores the date on the target.*1 Integer 1 31
DateAndTime.Hour Stores the hours on the target.*1 Integer 0 23
DateAndTime.Minute Stores the minutes on the target.*1 Integer 0 59
DateAndTime.Second Stores the seconds on the target.*1 Integer 0 59
DateAndTime.DayOfTheWeek Stores the day of the week on the target. Integer 0 6 -
Preferences.ScreenID Stores the ID of the current screen. Integer 1 9999
Preferences.ColorSetID Stores the project theme's color set.
1 Blue-Dark
2 Blue-Light
3 Green-Light
4 Green-Simple
5 Silver-Dark
6 Alarm
7 Test
8 Universal
9 Plasma
10 High Contrast
Integer 1 1000
Preferences.Brightness Stores the touch panel brightness. Range:

GP-4100 Series

ST6000 Series

STM6000 Series

0 to 15 (0 is bright).

SP5000 Series Power Box

SP5000X Series

0 to 100 (0 is bright).

(Except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

         
Preferences.LanguageID Stores the current language ID. See the Language Table editor for list of languages and associated IDs.          

Preferences.BacklightOff

If you set this property ON, the back light of the touch panel turns off.

(Except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

         

Preferences.USBStorage.Status

Displays the USB memory status.

(Except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

         
Preferences.SDCard.Status Displays the SD card status.

(SP5000 Series Power Box only)

         
Preferences.SystemKeypad.Status Displays the system keypad status.          
Preferences.KeepRuntimeData.UserManagement Stores the setting for keeping or overwriting user management data settings during File System transfer.          
Preferences.KeepRuntimeData.EthernetSettings

Stores the setting for keeping or overwriting Ethernet settings during File System transfer.

(Ethernet supported models except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

         
Preferences.SerialNumber

Displays the serial number of the display unit.

(ST6000 Series, STM6000 Series, and GP-4100 Series only)

         

Preferences.FileManagement.Status

Displays the File Management status.

When copy and paste is in operation, the value of this property is ON.

(Except the GP-4100 Series)

         

Preferences.WebViewer.ConnectedClients

Displays the number of Web Viewer clients connected to the HMI server (display unit).

(Except the GP-4100 Series)

         

Preferences.WebViewer.RemainedLockoutSeconds

A Web Viewer client is interacting with the HMI and therefore locking out other clients. After the client is idle, this property counts down the number of seconds until the lockout is released.

(Except GP-4100 Series)

         

Preferences.InputCompletedFromUSBBarcodeReader

Displays the data input status of a USB barcode reader.

The value of this source property is set ON when data read by a USB barcode reader is input to a variable.

After this source property value is set ON, manually turn it back OFF so you can confirm completion of the next input. (This property value is NOT turned OFF automatically.)

Connecting a USB Barcode Reader

         

Preferences.UWF.Status

Displays the status of the Windows® Unified Write Filter.

0: UWF is either not installed or UWF is disabled.

1: UWF is enabled (and the volume is protected from write operations).

(SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT only)

Note:

  • This property is updated at startup.
  • If the operating system on the display unit is Windows Embedded Standard 7, the value of this property may not update properly.
         

Ethernet1.MACAddress

Displays the MAC address for Ethernet port 1.

(Models with Ethernet port 1, except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series, PC/AT and models without Ethernet)

String     -

Ethernet2.MACAddress

 

Displays the MAC address for Ethernet port 2.

(Models with Ethernet port 2, except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

String     -

Ethernet1.IPv4Address

Displays the IP address of Ethernet port 1.

(Models with Ethernet port 1, except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series, PC/AT and models without Ethernet)

DWORD     -

Ethernet2.IPv4Address

 

Displays the IP address of  Ethernet port 2.

(Models with Ethernet port 2, except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

DWORD     -

Ethernet1.IPv4SubnetMask

Displays the Subnet Mask of Ethernet port 1.

(Models with Ethernet port 1, except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series, PC/AT and models without Ethernet)

DWORD     -

Ethernet2.IPv4SubnetMask

 

Displays the Subnet Mask of Ethernet port 2.

(Models with Ethernet port 2, except the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series and PC/AT)

DWORD     -
SecuritySettings.CurrentUserName Displays the current user name.          

SecuritySettings.CurrentUserGroupName

Displays the current group name.          
SecuritySettings.CurrentSecurityLevel Displays the current security level.          
SecuritySettings.UserNameEnter Set the user name used for login. Setting value is cleared after login operation.          
SecuritySettings.PasswordEnter Set the password used for login. Setting value is cleared after login operation.          
SecuritySettings.CurrentUserAvailableDay Displays the number of days remaining until you have to change the password.          
SecuritySettings.AutoPopupDialog Displays the login screen when you touch an object that has a security level higher than the logged-in user.          
SecuritySettings.ShowSecurityIcon Displays an icon on objects that have a higher security level than the logged-in user.          
SecuritySettings.LockStatus Displays the lock status.          
WebFunction.WebViewer.PageSettings.NodeName Displays the node name of the Web Viewer server. You can configure the node name in the [Node Name] property. [Node Name]

(Except GP-4100 Series)

         

*1 When writing to the SP5000 Series Open Box (Windows 10 IoT Enterprise Model), IPC Series or PC/AT, operate with the user rights that allow you to change the system time.

FTP

Property Description Data Type Minimum Value Maximum Value Read Write

Client.Status.ActiveClients

The number of sessions currently connected to the FTP server.

Integer 0 1 -

Connection[*].LastStatus

Note: * is the ID of the FTP connection.

Results of [Remote File Management] operations for each FTP connection. See List of LastStatus values below for more information.

This value is initialized to 0 when performing the [Remote File Management] operation.

Integer - - -

Connection[*].Terminate

Note: * is the ID of the FTP connection.

Forcibly terminates the FTP connection with the server.

Changing the value from 0 (OFF) to 1 (ON) forces the connection to terminate. Even if you change the value from 1 to 0 in the middle of the forced termination, the termination process cannot stop.

This value is initialized to 0 when performing the [Remote File Management] operation.

Bool 0 1

List of LastStatus values

Value Content Solution
1 Login or logout successful. -
100 Login failed. Unable to access the FTP server. Check the address of the FTP server. Also, check the state of the network.
110 Login failed. SSL/TLS connection failed.
  1. Check if the FTP server supports FTPS.
  2. Check that the TLS version of the FTP server is compatible with the display unit version.
  3. Check that the encryption suite of the FTP server is compatible with the display unit version.
  4. Confirm that SSL/TLS is not blocked on the communication path.
120 Login failed. The SSL/TLS connection failed. (The root certificate is invalid.) Check the contents of the root certificate file and retransfer the project.
130 Login failed. SSL/TLS connection failed. (Certificate validation failed.)
  1. Check that the server certificate is within the validity period.
  2. Check if the date and time of the display unit system are correct.
  3. Check that the certificate on the FTP server is correct.
160 Login failed. The user name or password is incorrect or has expired. Check your user name and password.
200

Failed to copy file from the FTP server to the display unit. Server error. (For example, the specified file does not exist)

Check the file path. Also check the file on the FTP server.
205

Failed to copy files from the display unit to the FTP server. Server error. (For example, you do not have write permission.)

Check the file path. Check if the file is writable on the FTP server.
210

Failed to copy files from the FTP server to the display unit. Communication error. (For example, the network is disconnected.)

Check the status of the network and the FTP server.
215

Failed to copy files from the display unit to the FTP server. Communication error. (For example, the network is disconnected.)

Check the status of the network and the FTP server.
220

Failed to copy files from the FTP server to the display unit. Display unit error. (For example, there is not enough space to write to.)

  1. Check if you have enough space to write to.
  2. Check that the path to the file you are writing to is correct.
  3. Check if the destination is write protected.
225

Failed to copy files from the display unit to the FTP server. Display unit error. (For example, the specified file does not exist.)

  1. Check if the read file exists.
  2. Check if the read file path is correct.
230 The file operation failed. The number of files exceeded 1000. Check the number of target files specified in the [Remote File Management] operation.
300 Transfer was forcibly terminated with the FTP connection's [Terminate] source property. -
400 File operation failed. There is a resource conflict. Check if multiple [Remote File Management] or [File Management] operations are running at the same time.
410 File operation failed. An unsupported file operation was run.
  1. Check if the source and destination are the same attribute (folder or file).
  2. Check that the specified file is in a supported file format.
  3. Check if the folder or file is an absolute path.
420 File operation failed. The external storage does not exist.

Note: Error code 420 appears when the display unit is not an SP5000 Series Open Box (Windows 10 IoT Enterprise model), IPC Series, or PC/AT. Error code 220 or 225 appears when the display unit is an SP5000 Series Open Box (Windows 10 IoT Enterprise model), IPC Series, or PC/AT.

Check if the external storage is installed on the display unit.