Variables

Property Description Data Type Minimum Value Maximum Value Read Write
InitialValue Stores the initial value for the internal variable. BOOL, Integer, Real, Date, Time, Date And Time, String Default value of the selected data type. Default value of the selected data type. -
Min Stores the minimum value for data input to the variable. BOOL, Integer, Real, Date, Time, Date And Time, String Default value of the selected data type. Default value of the selected data type. -
Max Stores the maximum value for data input to the variable. BOOL, Integer, Real, Date, Time, Date And Time, String Default value of the selected data type. Default value of the selected data type. -
Value Stores the variable value. BOOL, Integer, Real, Date, Time, Date And Time, String Default value of the selected data type. Default value of the selected data type.
Quality

Note: This property is not available for local variables.  

 

Displays the scan status of the selected variable.

Value Description
0, 4

Access to device address and device address value is normal.

1, 3, 5, 7

Cannot access the device address.

6

After the display unit starts and accesses the device address, the display unit is in a waiting state, until the device address value becomes available.

8, 12

Device address value is invalid.

9, 13, 15

You cannot access the device address. Also, the device address value can be invalid.

2, 10, 11, 14

Not in use

BYTE 0 15 -