Meanings of the front LED status and indications

The following table shows meanings of front LED status and indications in each IPC product.
SeriesModelsFront LED
StatusIndication
PL-3000 Series (with a monitor)APL3600/3700/3900Click hereClick here
PL-x930 SeriesPL6930/6931/7930/7931Click here
PL-x920 SeriesPL6920/6921/7920/7921Click here
PL-5910 SeriesPL5910/5911Click here
PL-5900 SeriesPL5900/5901Click here
PS-3000A Series (with a monitor)PS-3450A/PS-3451A/
PS-3710A/PS-3711A
Click here
PS-3700A/PS-3701AClick here
PS-3650A/PS-3651AClick here
FP-2000 and FP-3000 SeriesFP3500/3600/3650/3700/3710/
2500/2600/2650
Click hereClick here
PS-3600GPS-3600GClick hereClick here



List of the front LED status (in the PL3000 series with a monitor)

List of the front LED status (in the PLx930 series)

List of the front LED status (in the PLx920 series)

List of the front LED status (in the PL5910 series)

List of the front LED status (in the PL5900 series)

List of the front LED status (PS-3450A / PS-3451A / PS-3710A / PS-3711A)

List of the front LED status (PS-3700A / PS-3701A)

List of the front LED status (PS-3650A / PS-3651A)

List of the front LED status (in the FP2000 and FP3000 series)

List of the front LED status (PS-3600G)

Meanings of the front LED status and indications (in the PL and PS series)
LED StatusIndication
Software Off
System Stop
The same status as after completion of Windows shutdown process.
It is not in abnormal status even though the system is not working.
System Monitor Error
RAS Error
Some kind of a RAD error occurred
(In the case that the setting of LED error action is ON in the property of System Monitor)
Open System Monitor by clicking the icon on a task bar to check where the error occurs.
Touch Panel Self-Test ErrorIn the case that there is no error occurring in System Monitor, since a user cannot cope with the error on their own, please ask for repair of the IPC unit.
Software Mirror Disk Error
Hardware Mirror Disk Error
(Only in the models supporting Mirror Disk)
An error is detected in the configuration for mirroring.
Please take action on the error after confirming the configuration at the moment.

Software Mirroring Utility (PL-SM900) User Manual
- Monitoring via the RAS System Monitor

Mirror Disk Unit (PL-MD200) Installation Guide
- HDD Installation
Backlight ErrorAn error on backlight is detected.
Consider a replacement of the backlight.
System in operation with battery
System in standby with battery
PS-365xA
The status shows that a battery is working, in the case that a unit is equipped with a Battery Unit as an option.
Meanings of the front LED status and indications (in the FP2000 and FP3000 series)
LED StatusIndication
Orange litNormal operation in a FP unit, but a display signal from a connected device is not detected.
Green/Red blinking
Orange blinking
An error on backlight is detected.
Consider a replacement of the backlight.
Meanings of the front LED status and indications (PS-3600G)
LED StatusIndication
Lit by the RAS feature(In the case that the setting of LED error action is ON in the property of System Monitor)
Open System Monitor by clicking the icon on a task bar to check where the error occurs.

PS-3600G Series User Manual
- RAS Control
- Processing Functions
System ErrorAn error is detected in start-up data. Consider performing recovery of CF card.

PS-3600G Series User Manual
- Recovery













Did this answer your question?