[Communication Drivers] Siemens AG TIA Portal Ethernet Driver

Summary

Last Updated: July 30, 2019

Details

Caution
Precautions for adding a new driver onto Windows Vista or later
Precautions for adding a new driver at Daylight Saving Time
Title Siemens AG TIA Portal Ethernet Driver
Version Ver. 1.14.08
Supported Software The required versions of software for this driver installer are as follows.
Model Required driver version
GP4100 Series (GP-4114T)
GP4000 Series
GP4000H Series
SP5000 Series (SP-5B10)
GP-Pro EX
Ver. 4.06.300 or later
Pro-Server EX
Ver. 1.31.000 or later
SP5000 Series (SP-5B00, SP-5B90) GP-Pro EX
Ver. 4.08.200 or later
Pro-Server EX
Ver. 1.37.000 or later
SP5000 Series (SP-5B41, SP-5B40)
IPC Series for WinGP
General PCs for WinGP
GP-Pro EX
Ver. 4.05.100 or later
Pro-Server EX
Ver. 1.31.000 or later
You can check your version by "Help" function → "Version Info".
Supported Devices
  • S7-1200 Series
  • S7-1500 Series
Supported Units Required versions depend on models.
Please check "Supported Models / Version" or the required versions of GP-Pro EX.

Required driver versions for different models are listed below
Model Required driver version
GP4100 Series (GP-4114T) Ver. 1.11.01 or later
GP4000 Series Ver. 1.11.01 or later
GP4000H Series Ver. 1.11.01 or later
SP5000 Series (SP-5B10) Ver. 1.11.01 or later
SP5000 Series (SP-5B00, SP-5B90) Ver. 1.11.01 or later
SP5000 Series (SP-5B41, SP-5B40) Ver. 1.10.00 or later
IPC Series for WinGP Ver. 1.10.00 or later
General PCs for WinGP Ver. 1.10.00 or later
Device/PLC
Connection Manual
For details, please read the "Device/PLC Connection Manual" in the lower part of this page.
For general information regarding Device connection and documentation conventions, please refer to "Device/PLC Connection Manual".
Updated Contents Ver 1.14.08 The following feature was supported.
  • The mode is changed to overwrite from skip if tags already registered when import.
The following issue was fixed.
  • An unknown address error was displayed if set multiple nodes on Ver.1.14.07.
Notes When using GP-Pro EX before Ver. 4.06.000. Please make sure to transfer a GP-Pro EX project by "All transfer project" every time tag import has been executed.
Limitations Depending on the data size of imported TIA Portal project, transferring GP-Pro EX project data may be failed. Even if transferring is completed, an error message may be displayed when the display starts up. In that case, please delete unused tags from the TIA Portal project you will import. After that, please try to re-import.

How to install (This is a self-extracting file.)

Prior to installation, be sure to close all software applications that are running.

  1. Click on the above file name to download the data to desired folder.
  2. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
  3. After the installer starts, follow the instructions given on each screen.
  4. After installation, execute GP-Pro EX.
  5. Select [Siemens AG] for "Manufacturer" and [TIA Portal Ethernet] for "Series" in [Device/PLC] settings of [System Settings] on the [Project] menu.
When using the driver, be sure to refer to the Device Connection Manual PDF (Shown above). Also, for general information regarding Device connection and documentation conventions please refer to "Device/PLC Connection Manual".

Terms of use / Cautions

Please be acknowledged of the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions

Download file

Installer :
25.38 MB (26,615,480Byte)
Last update: 2019/07/23
Device/PLC Connection Manual :
323.05 KB (330,799Byte)
Last update: 2019/07/23
Device/PLC Reference Manual :
328.26 KB (336,139Byte)
Last update: 2019/07/23

Update history

  • Ver 1.14.08 The following feature was supported.
    • The mode is changed to overwrite from skip if tags already registered when import.
    The following issue was fixed.
    • An unknown address error was displayed if set multiple nodes on Ver.1.14.07.
  • Ver 1.14.07 The following feature was supported.
    • Reduce memory usage by import with filtering necessary tag information.
    The following issue was fixed.
    • By supported to TIA Portal V15.1, some projects become impossible import.
  • Ver 1.14.06 The following feature was supported.
    • Support the function block (FB) as data type.
  • Ver 1.14.05 The following feature was supported.
    • TIA portal V15.1
    • Import project with including group
    The following issue was fixed.
    • The import process was canceled in V1.13.02 or later, In the case importing a project with including data type "Timer", if the selected PLC does not support this data type.
  • Ver 1.13.04 The following issue was fixed.
    • In the Individual Device Settings dialog box, using [Edit] to import tags sometimes caused variables used by parts on the screen to become "Undefined".
  • Ver 1.13.03 The following feature was supported.
    • The indicator for limitation size of TIA portal project was added on Individual Device Setting.
  • Ver 1.13.02 The following feature was supported.
    • TIA Portal V15
    The following issue was fixed.
    • Some TIA Portal projects cannot be opened when importing the TIA Portal project.
  • Ver 1.12.02 (Included in GP-Pro EX Ver. 4.07.300) The following feature was supported.
    • TIA Portal V14
  • Ver 1.11.01 (Included in GP-Pro EX Ver. 4.07.000) The following issues were fixed.
    • Importing the unnamed structure was failed.
    • Some TIA Portal projects cannot be opened when importing the TIA Portal project.
  • Ver 1.11.01 The following models were supported.
    • GP4100 Series (GP4114)
    • GP4000 Series
    • GP4000H Series
    • SP5000 Series (SP5B10)
    The following issue is fixed:
    • Grouped Data blocks and PLC tags cannot be imported.
  • Ver 1.10.00 New