The following describes the specifiable content of Operand (S2) in the FLMV and FLMVP instructions.
|
Name |
Type |
Condition |
Number of Steps in the Operand |
Possible |
|---|---|---|---|---|
|
Connection Device Address |
Bit |
— |
— |
- |
|
Word |
Specify by words only |
1 |
|
|
|
Internal Address |
Bit |
— |
— |
- |
|
Word |
Specify by words only |
1 |
|
|
|
Symbol |
Bit |
— |
— |
- |
|
Word |
— |
1 |
|
|
|
Variable Format |
Bit |
Specify a bit |
— |
- |
|
Specify bit array ([constant]) |
— |
- |
||
|
Specify bit array ([variable]) |
— |
- |
||
|
Integer |
Arrays and modifiers are not specified |
1 |
|
|
|
Specify integer variable [constant] |
— |
- |
||
|
Specify integer variable [variable] |
— |
- |
||
|
Specify integer variable [constant/variable] |
— |
- |
||
|
Float |
— |
— |
- |
|
|
Specify float variable [constant] |
— |
- |
||
|
Specify float variable [variable] |
— |
- |
||
|
Real |
— |
— |
- |
|
|
Specify real variable [constant] |
— |
- |
||
|
Specify real variable [variable] |
— |
- |
||
|
Timer |
.PT/ .ET only |
2 |
|
|
|
Counter |
.PV/ .CV only |
2 |
|
|
|
Date |
.YR/ .MO/ .DAY only |
2 |
|
|
|
Time |
.HR/ .MIN/ .SEC only |
2 |
|
|
|
PID |
.KP/ .TR/ .TD/ .PA/ .BA/ .ST only |
2 |
|
|
|
Address Format |
X_ |
— |
— |
- |
|
Y_ |
— |
— |
- |
|
|
M_ |
— |
— |
- |
|
|
I_ |
— |
1 |
|
|
|
Q_ |
— |
1 |
|
|
|
D_ |
Modifiers are not specified |
1 |
|
|
|
D_****.B/W [constant] |
— |
- |
||
|
D_****.B/W [address] |
— |
- |
||
|
F_ |
— |
— |
- |
|
|
R_ |
— |
— |
- |
|
|
T_ |
.PT/ .ET only |
2 |
|
|
|
C_ |
.PV/ .CV only |
2 |
|
|
|
N_ |
.YR/ .MO/ .DAY only |
2 |
|
|
|
J_ |
.HR/ .MIN/ .SEC only |
2 |
|
|
|
U_ |
.KP/ .TR/ .TD/ .PA/ .BA/ .ST only |
2 |
|
|
|
Constant |
— |
1 to 4096 (Maximum number of arrays) |
1 |
|