Error Code
MP Series
|
Error Code |
Description |
|
0x90 |
Transfer error |
|
0x92 |
Illegal parameter |
|
0x96 |
Register No. over |
|
0x9C |
File is modified |
|
0x9D |
Data access error |
Inverter Series
|
Error Code |
Description |
|
0x01 |
Function code error |
|
0x02 |
Invalid register number error |
|
0x03 |
Invalid quantity error |
|
0x21 |
Data setting error |
|
0x22 |
Write mode error |
|
0x23 |
Main circuit undervoltage (UV) error during write |
|
0x24 |
Write error during processing of constants |
Servo Series
|
Error Code |
Description |
|
0x01 |
Function Code Error
|
|
0x02 |
Faulty Register Number
|
|
0x03 |
Faulty Quantity
|
|
0x30 |
Faulty Register Number (High Level)
|
|
0x31 |
Access Limit Error
|
|
0x32 |
Outside Setting Range Error
|
|
0x33 |
Data Matching Error
|
|
0x34 |
Condition Error
|
|
0x35 |
Process Conflict Error
|
|
0x36 |
Axis number error (Σ-7W/Σ-7C series only)
|
I/O (M-System)
|
Error Code |
Description |
|
0x01 |
Function Code Error
|
|
0x03 |
Faulty Quantity
|
|
0x04 |
Data Type Error
|
|
0x09 |
Process Conflict Error
|
|
0x81 |
Protocol ID Setting Error
|
|
0x82 |
Data Length Setting Error
|
|
0x83 |
Vendor Special Area Error
|
Example:
Error code = 0x83, and the vendor special error code = 0x01, it is displayed 83,01.
Vendor special error code
|
Error Code |
Description |
|
0x01 |
Model code error
|
|
0x02 |
Specified channel error
|
|
0x03 |
Setting command error
|
|
0x04 |
Setting command data error
|
- If the error code is 0x83, it is displayed together with the vendor special error code.
I/O (Azbil)
|
Error Code |
Description |
|
0x01 |
Function Code Error
|
|
0x02 |
Memory Address Error
|
|
0x03 |
Faulty Quantity
|
|
0x04 |
Data Type Error
|
|
0x81 |
Protocol ID Setting Error
|
|
0x82 |
Data Length Setting Error
|
|
0x83 |
Vendor Special Area Error
|
Vendor special error code
|
Error Code |
Description |
|
0x01 |
Azbil protocol ID setting error
|
Example:
Error code = 0x83, vendor special error code = 0x81, and Modbus error code = 0x01, it is displayed 83,81,01.
Vendor special error code
|
Error Code |
Description |
|
0x81 |
MODBUS RTU abnormal response
|
Modbus error code
|
Error Code |
Description |
|
0x01 |
Illegal function
|
|
0x02 |
Illegal data address
|
|
0x03 |
Illegal data
|
|
0x13 |
Write mode error |
- If the error code is 0x83, and the vendor special error code is 0x01, it is displayed 83,01.
- If the error code is 0x83, and the vendor special error code is 0x81, it is displayed together with the Modbus error.
Stepping (ORIENTAL MOTOR)
|
Error Code |
Description |
|
0x01 |
Function Code Error
|
|
0x02 |
Faulty Register Number
|
|
0x03 |
Faulty Quantity
|
|
0x04 |
Data Type Error
|
|
0x05 |
Access Limit Error
|
|
0x06 |
Outside Setting Range Error
|
|
0x07 |
Data Matching Error
|
|
0x08 |
Condition Error
|
|
0x09 |
Process Conflict Error
|