1:1 Connection

1:n Connection


Examples of communication settings of the Display and the External Device, recommended by Pro-face, are shown.
WARNING
UNINTENDED EQUIPMENT OPERATION
Read and understand the instructions in this section to ensure data is properly transferred.
The following cable diagrams may be different from cable diagrams recommended by External Device Manufacturer.
Please be assured there is no operational problem in applying the cable diagram shown in this manual.
The FG pin of the External Device body must be grounded according to your country's applicable standard. Refer to your External Device manual for details.
SG and FG are connected inside the Display. When connecting the External Device to SG, design your system to avoid short-circuit loops.
Connect an isolation unit if the communication is not stable due to noise or other factors.
Range of supported device address is shown in the table below. Please note that the actually supported range of the devices varies depending on the External Device to be used. Please check the actual range in the manual of your External Device.
WARNING
UNINTENDED EQUIPMENT OPERATION
:
As
shown in the following table, you may need to enter "9999"
(meaning an invalid parameter setting or the like) depending upon
the parameter types. In this case, the data written and read from
the Display
is as follows:
Inverter Series |
Inverter Setting |
Written Data |
Read Data |
|---|---|---|---|
FR-S500/FR-F500J series |
--- |
-1 (0xFFFF) |
-1 (0xFFFF) |
888 |
-16 (0xFFF0) |
-16 (0xFFF0) |
|
Series other than above |
9999 |
-1 (0xFFFF) |
-1 (0xFFFF) |
8888 |
-16 (0xFFF0) |
-16 (0xFFF0) |
Word Address |
FR-E700 series |
FR-E500 series |
FR-S500 series |
FR-F500J series |
|---|---|---|---|---|
S00 |
Operation mode |
Operation mode |
Operation mode |
Operation mode |
S01/SL01*1 |
Output frequency/speed |
Output frequency[speed] |
Output frequency[speed] |
Output frequency[speed] |
S02 |
Output current |
Output current |
Output current |
Output current |
S03 |
Output voltage |
Output voltage |
- |
- |
S04/SL04*1 |
Special monitor |
- |
- |
- |
S05 |
Special monitor selection No. |
- |
- |
- |
S06/SL06*1 |
Output frequency |
- |
- |
- |
S07 |
Output current |
- |
- |
- |
S08 |
Output voltage |
- |
- |
- |
S09/SL09*1 |
Frequency setting |
- |
- |
- |
S10 |
- |
- |
- |
- |
S11 |
Motor torque |
- |
- |
- |
S12 |
Converter output voltage |
- |
- |
- |
S13 |
Regenerative brake duty |
- |
- |
- |
S14 |
Electronic thermal relay function load factor |
- |
- |
- |
S15 |
Output current peak value |
- |
- |
- |
S16 |
Converter output voltage peak value |
- |
- |
- |
S17 |
- |
- |
- |
- |
S18 |
Output power |
- |
- |
- |
S19 |
Input terminal status |
- |
- |
- |
S20 |
Output terminal status |
- |
- |
- |
S21 |
- |
- |
- |
- |
S22 |
- |
- |
- |
- |
S23 |
- |
- |
- |
- |
S24 |
Cumulative energization time |
- |
- |
- |
S25 |
- |
- |
- |
- |
S26 |
Actual operation time |
- |
- |
- |
S27 |
Motor load factor |
- |
- |
- |
S28 |
Cumulative power |
- |
- |
- |
S29 |
- |
- |
- |
- |
S30 |
- |
- |
- |
- |
S31 |
- |
- |
- |
- |
S32 |
- |
- |
- |
- |
S33 |
- |
- |
- |
- |
S34 |
- |
- |
- |
- |
S35 |
PID set point |
- |
- |
- |
S36 |
PID measured value |
- |
- |
- |
S37 |
PID deviation value |
- |
- |
- |
S38 |
Option input terminal status1 |
- |
- |
- |
S39 |
Option input terminal status2 |
- |
- |
- |
S40 |
Option output terminal status |
- |
- |
- |
S41 |
Motor thermal load factor |
- |
- |
- |
S42 |
Inverter thermal load factor |
- |
- |
- |
S43 |
Alarm definition (Latest Nos. 1&2) |
Alarm definition (Latest Nos. 1&2) |
Alarm definition (Latest Nos. 1&2) |
Alarm definition (Latest Nos. 1&2) |
S44 |
Alarm definition (Latest Nos. 3&4) |
Alarm definition (Latest Nos. 3&4) |
Alarm definition (Latest Nos. 3&4) |
Alarm definition (Latest Nos. 3&4) |
S45 |
Alarm definition (Latest Nos. 5&6) |
Alarm definition (Latest Nos. 5&6) |
- |
- |
S46 |
Alarm definition (Latest Nos. 7&8) |
Alarm definition (Latest Nos. 7&8) |
- |
- |
S47 |
Run command (extended) |
- |
- |
- |
S48 |
Run command |
Run command |
Run command |
Run command |
S49 |
Inverter status monitor (extended) |
- |
- |
- |
S50 |
Inverter status monitor |
Inverter status monitor |
Inverter status monitor |
Inverter status monitor |
S51/SL51*1 |
Set frequency read (RAM) |
Set frequency read (RAM) |
Set frequency read (RAM) |
Set frequency read (RAM) |
S52/SL52*1 |
Set frequency read (EEPROM) |
Set frequency read (EEPROM) |
Set frequency read (EEPROM) |
Set frequency read (EEPROM) |
S53/SL53*1 |
Set frequency write (RAM) |
Set frequency write (RAM) |
Set frequency write (RAM) |
Set frequency write (RAM) |
S54/SL54*1 |
Set frequency write (RAM, EEPROM) |
Set frequency write (EEPROM) |
Set frequency write (RAM,EEPROM) |
Set frequency write (RAM,EEPROM) |
S55 |
Inverter reset |
Inverter reset |
Inverter reset |
Inverter reset |
S56 |
Alarm definition all clear |
Alarm definition batch clear |
Alarm definition batch clear |
Alarm definition batch clear |
S57 |
All parameter clear |
All parameter clear |
All parameter clear |
All parameter clear |
S58 |
Link parameter extended setting |
Link parameter expansion setting |
Link parameter expansion setting |
Link parameter expansion setting |
S59 |
Second parameter changing |
Second parameter changing |
Second parameter changing |
Second parameter changing |
*1Available
device differs depending on the settings of the External Device.
Use the S device and the SL device for 4-byte data length and
6-byte data length, respectively. |